bcee4405

4.4.12. Removal and installation of a cover of the GRM drive

Below the described procedure assumes that the power unit is removed from the car.

The components removed for ensuring access to a GRM drive cover

1 — the Probe of level of motive oil
2 — the Intermediate roller

3 — the Pump GUR
4 — the Water pump


 PERFORMANCE ORDER

  1. Take out the probe of level of motive oil and shoot an intermediate video (2 on an illustration). Remove the pump GUR and its arm with a lifting eye (3 on an illustration).
  2. Remove the water pump and the plug with sealing rings (4 on an illustration).
  3. Remove the pallet of a case and disconnect from it a hose of a sapun of a case. Leave the directing plug in the block of cylinders. Wipe the flowed-out oil.
  4. Remove a pulley of a bent shaft (see the Section Replacement of Epiploons and Pulley of a Bent Shaft).
  1. Turn out the directing pins from a GRM drive cover by cutting of a carving (8) in them (fixture (8 and 9) of a cover (10) of the GRM drive).
  1. Turn out all bolts of fastening of a cover of the GRM drive (9 on an illustration).
  2. Uncover, since its bottom edge, and then, moving it up-down not to damage laying of a head of cylinders.
  3. Carefully clear all interfaced surfaces of the consolidation remains and then apply on them on the center the roller of Loctite 518 sealant 1 mm thick.
  4. Establish a GRM drive cover, and screw bolts of its fastening, but do not tighten them yet. Establish into place the directing cover pins.
  5. Tighten bolts of fastening of a cover of the GRM drive with effort of 22 N • m.
  6. Check a condition of sealing rings of the water pump and if necessary replace them.

Further installation is made as it should be, the return to an order of dismantle of components.