4.4.12. Removal and installation of a cover of the GRM drive
|
Below the described procedure assumes that the power unit is removed from the car. |
The components removed for ensuring access to a GRM drive cover
|
- Take out the probe of level of motive oil and shoot an intermediate video (2 on an illustration). Remove the pump GUR and its arm with a lifting eye (3 on an illustration).
- Remove the water pump and the plug with sealing rings (4 on an illustration).
- Remove the pallet of a case and disconnect from it a hose of a sapun of a case. Leave the directing plug in the block of cylinders. Wipe the flowed-out oil.
- Remove a pulley of a bent shaft (see the Section Replacement of Epiploons and Pulley of a Bent Shaft).
|
- Turn out the directing pins from a GRM drive cover by cutting of a carving (8) in them (fixture (8 and 9) of a cover (10) of the GRM drive).
|
- Turn out all bolts of fastening of a cover of the GRM drive (9 on an illustration).
- Uncover, since its bottom edge, and then, moving it up-down not to damage laying of a head of cylinders.
- Carefully clear all interfaced surfaces of the consolidation remains and then apply on them on the center the roller of Loctite 518 sealant 1 mm thick.
- Establish a GRM drive cover, and screw bolts of its fastening, but do not tighten them yet. Establish into place the directing cover pins.
- Tighten bolts of fastening of a cover of the GRM drive with effort of 22 N • m.
- Check a condition of sealing rings of the water pump and if necessary replace them.
|
|
Further installation is made as it should be, the return to an order of dismantle of components.